Doorking PC Compatible Multi-Door Access Controller 1838 Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 49
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
2.3 WIRING DETAIL
2.3.1 Controller Only
C.O.
PHN
Elevator
Control
RS 232
Connection
Auxiliary Terminals
Main Terminal
Relay 0
4 5
1833, 1834, 1835, 1837, 1838 CONTROLLER
30 Series Controller Detail Wiring
NOTES: Relay 0 is not available on the 1834 or 1838 controller.
1
2
3
4
5
6
1
2
3
123 1716151413 2019
NO
NC
COM
14
13
12
11
10
9
8
7
6
5
4
3
2
1
94
NEG 12 VDC INPUT
POS 12 VDC INPUT
16 VAC
OUTPUT
3
46 18
- 12 VDC BATT INPUT
+12 VDC BATT INPUT
1
2
3
7
DOORKING, INC., INGLEWOOD, CA 90301
Date: Dwg. No. Rev.
Title:
7/04
B
M1835-065-2
Detail Wiring - 30 Series Controller
RELAY 1 NORMALLY OPEN
RELAY 1 NORMALLY CLOSED
RELAY 1 COMMON
RELAY 2 CONTACT
RELAY 2 COMMON
RED
BLK
WHT
GRN
+ 12 VDC
COMMON
DATA 1
DATA 0
CARD
RDR-1
RED
BLK
WHT
GRN
+ 12 VDC
COMMON
DATA 1
DATA 0
ELEVATOR
CONTROL
2348-010
WHT
GRN
BLK
DATA 1
DATA 0
COMMON
20
21
22
7
8
6
16 Volt, 20 VA UL Listed Transformer.
Battery Backup - separate batteries required for phone
system and weigand terminals.
1
Central Office phone line - touch tone, loop start.
2
A switch closure across terminals 4 & 6 will activate relay 1
for its programmed strike time.
3
4
5
6
For 1837, use 16 Volt, 40 VA UL Listed Transformer.
Belden 9418 or Equivalent. If card reader is lighted, Belden
9931 can be used to provide extra wires for light power.
RELAY 0 NORMALLY OPEN
RELAY 0 NORMALLY CLOSED
RELAY 0 COMMON
See Dwg No. M1835-065-5 for detail.
8
See Elevator Control Board Manual 2348-065 for detail.
9
Aux power transformer must be connected. Otherwise, RS232,
elevator control and weigand inputs will not function.
10
10
16 VAC output can be used to power lights on card readers that
have additional lighting for outdoor use.
11
12
12
11
Card reader connected to these terminals will operate Relay 1
for its programmed strike time.
Card reader connected to these terminals will operate Relay 2
for its programmed strike time.
13
13
Relay 2 contact is set N.O or N.C. with a jumper on the circuit
board.
14
Electric strikes are wired to Normally Open (N.O.) contacts;
magnetic locks are wired to the Normally Closed (N.C.) contacts.
15
Power for electric strikes or magnetic locks is not provided by the
system. Use a separate UL listed power supply.
16
16
16
Auxiliary and Elevator Control terminals are not available on the
1834 controller.
6
6
CARD
RDR-2
BLK
RED
12 VDC
BATT
17
17
17
Use 18 AWG wire for runs up to 100 Ft. Use 16 AWG wire for
runs up to 200 Ft.
DOOR
LOCK
To Control
Relay
14
15
BASIC DOOR CONTROL
CARD
READER
To Card
Reader Input
16 VAC
PWR
INPUT
16 VAC
PWR
INPUT
LOCK
PWR
Page 16 1838-065-L-3-10
Vue de la page 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 48 49

Commentaires sur ces manuels

Pas de commentaire